Building with Sto

HeroShot

Aorangi House - 5 GreenStar. Practice - Studio of Pacific Architecture LTD. Before and After Image.

StoTherm Masonry

StoTherm Masonry Insulation System - BRANZ Appraisal Certificate 604 (2008)

Introduction

New requirements for better energy efficiency

In August 2007 the Department of Building and Housing announced major changes to Clause H1 of the Building Code, which deals with energy efficiency, thermal storage and insulation. The changes include, amongst other things, increased insulation requirements and the increased recognition of the appropriate use of thermal mass. The changes affect all houses, and other buildings that have a floor area less than 300m2.

 

 

    Zone 1
    Zone 2
    Zone 3
New R-Values for Different Zones
  R-Values Timber R-Values Solid Masonry
Roof  2.9  2.9  3.3  3.5  3.5  3.5
Wall  1.9  1.9  2.0  0.8  1.0  1.2
Floor  1.3  1.3  1.3  1.5  1.5  1.5
Vertical
Glazing
 0.26  0.26  0.26  0.26  0.26  0.26
Skylights  0.26  0.26  0.31  0.26  0.26  0.31

Internal Insulation

(must meet timber R-V)

StoTherm-Masonry Insulation

R-V
1.9

R-V
1.9

R-V
2.0

Masonry
Insulation

60mm
panel

(meets all
R-Values)

R-V
1.5

80mm
panel

(meets all
R-Values)

R-V
2.0

100mm
panel

(meets all
R-Values)

R-V
2.5

(standard 100x50 framing)

 

Different insulation options have different effects on the physical properties of a building.

Sto's External insulation offers significant advantages; it offers a favourable temperature curve and shields the substrate from thermal shocks. There are no cold bridges and the existing heat retention capabilities of solid masonry walls are fully utilised, interstitial condensation can be eliminated irrespective of climate conditions. The internal wall temperature increases which reduces the risk of condensation, damp and mould.

 

While internal insulation allows a room to be heated quickly, that's about its only plus point. Its temperature curve is poor, and the external wall remains vulnerable to the elements. The heat retention capability of the existing wall is not utilised in winter, and it is susceptible to an internal dew point resulting in condensation, damp and mould. In summer the process is reversed with the masonry wall heating the interior environment. Note: When insulating internally only, masonry walls need to meet the timber insulation requirements.

 

Brochure

Download brochures for your electronic reference or product library.

 

Brochure
StoTherm Energy Efficiency
PDF

 

Photos

Click here for additional photos. Click on a thumbnail for a larger image and description.

 

Image 1 Image 2 Image 2 Image 3
Image 5 Image 6 Image 7 Image 8
Image 9 Image 10 Image 11 Image 12
Image 13 Image 14

 

Click here to hide images.
Case Study

Download brochures for your electronic reference or product library.

 

Case Study
Aorangi House - 5 GreenStar
PDF
Case Study
Temperature Curve - U Values (80 mm)
PDF

 

Sto System

StoTherm Masonry System

StoTherm Classic Masonry has now been the international benchmark in the field of facade insulation for over 40 years.


Its shock proof and impact resistance is up to 6 times higher than that of mineral cement based systems offering the utmost in fracture prevention. It consists of a co-ordinated systematic approach providing the optimum insulation requirements for concrete block construction. For a component break-down of the StoTherm Insulation System, please refer to the StoArmat Miral StoTherm Insulation System brochure.

 

Click on each of the layers below to see the components of the StoTherm Masonry System.

 

 

Component Builder

 

01

Adhesive: Gluecoat Mortar

 

 

02

Insulation: Expanded Polystyrene Sheet

60/100mm "H" grade self-extinguishing sheet, manufactured to AS 1366 Part 3 by an approved manufacturer.

 

poly

03

Sto Therm Anchor

The Anchors are installed countersunk and capped with ST Insulation Cap to avoid thermal bridging.

 

Click here to view the procedure.

 

04

Basecoat: LevelLite 6/8 mm

Lightweight EPS bead mineral plaster with good build properties, water retention agents and machine application properties.

 

sto-bag

 

 

05

Reinforcement: StoArmat RFP

European manufactured and certified, strong, malleable, impact resistant, white reinforcing plaster in a pail. Contains a calibration grain ensuring correct mesh coat thickness. (No cement)

 

sto bucket

 

 

06

Plus: Sto European mesh

Easy to install, meets the highest requirements for crack, stress and alkalinity resistance.

 

sto-mesh

 

07

Finishing Render: Stolit range

European manufactured and certified, organically
bound, strong, hard wearing, impact resistant, pre
coloured finishing renders. (No cement)

 

 

Stolit K - (1mm/1.5mm/2mm/3mm)coloured finishing render. A range of coloured float finished self gauging granulated finishes.

 

Stolit MP & MP Natural - coloured finishing render. A range of coloured fine sponge finishes.

08

Coating:

StoColor Maxicryl - matt facade paint.


 

StoLastic Color - satin matt facade paint European manufactured and certified durable facade paints available in a full range of colours.

Click here to download the TDS.

 

StoLotusan Color G - mineral silicone resin European manufactured and certified self cleaning mineral paint with a breathable structure, in a full range of colours. Not recommended in dark or strong tints.

.

 

sto-bucket

 


 

 

Stolit: Coloured Finishing Renders

Stolit organic finishing renders are manufactured in Europe and certified around the world. They have been in successful use for over 50 years on a variety of different substrates. During this time they have undergone a continual process of optimisation.

 

The perfect combination of properties:Durable, strong, hardwearing, impact resistant, malleable, weather resistant, colour stable and highly resistant to micro-organism. They are designed with good vapour permeability to allow the building to breathe while still repelling liquid water. All renders are easy to apply and can be tinted from the StoColor System or matched to the colour of your choice, using the Sto spectrometer.

 

Coloured Self-Gauging Float Finish Renders:

StolitK 1.0mm StolitK 1.5mm StolitK 2.0mm StolitK 3.0mm

StolitK 1.0mm

TDS / TDS Quick Setting

StolitK 1.5mm

TDS / TDS Quick Setting

StolitK 2.0mm

StolitK 3.0mm

 

StoTherm Classic System:

StolitK MP StolitK MP Natural    

Stolit MP

TDS / TDS Quick Setting

Stolit MP Natural

   

 

The Perfect Finish: Competence in Colour

The well-aimed use of colour in a manner which complements the architecture is subject to specific laws. The StoColor System provides a clear framework and a systematic approach to colour design based on subtly nuanced colour concepts of high aesthetic appeal. The StoColor System eschews colorimetric logic in favour of human perception of colour. It is based primarily on the colours yellow, orange, red, violet, blue and green. These six sections are then mixed to form the 24 basic tones which correspond to the 24-part colour wheel.

Sto Colour Wheel

 

Specification

Download a technical specification for StoTherm Masonry from the list below. This specification is also integrated into the MasterSpec - 4282 SR - Masonry. (StoTherm Masonry) and 4285 S - Insulation (StoTherm). If you have any questions, please do not hesitate to contact us for technical support.

 

SS-207
StoTherm Masonry Insulation System
PDF

 

StoArmat Miral and StoTherm is appraised by BRANZ. Click below to download the BRANZ Appraisal Certificate.

 

BRANZ Appraisal
BRANZ Appraisal Certificate 604 (2008) - StoTherm / Masonary
PDF

 

 

Technical Details

Download CAD or PDF details for your project. Use the interactive detail selector below - roll over the hot spots to find and download the appropiate detail:

StoHouse - Technical Detail Selector

CB-101

Sto Concrete Block Plaster System

DWGDXFPDF

CB-102

StoArmat Miral Plaster System - Cross Section

DWGDXFPDF

CB-200

Sto Concrete Block Foundation

DWGDXFPDF

CB-201

Sto Concrete Block Foundation - Insulating Plaster

DWGDXFPDF

CB-300

Sto Concrete Block Horizontal / Sloping Soffit

DWGDXFPDF

CB-301

Sto Concrete Block Inclining Soffit

DWGDXFPDF

CB-400

Sto Concrete Block Control Joints

DWGDXFPDF

CB-401

Sto Concrete Block Expansion Joint Between Dissimilar Materials

DWGDXFPDF

CB-550

Sto Concrete Block Aluminium Head / Sill Detail

DWGDXFPDF

CB-552

Sto Concrete Block Timber Head / Jamb / Sill Detail

DWGDXFPDF

CB-551

Sto Concrete Block Aluminium Head / Sill with Insulating Plaster

DWGDXFPDF

CB-552

Sto Concrete Block Timber Head / Jamb / Sill Detail

DWGDXFPDF

 

Alternatively, select the link below to download a complete set of details below:

 

CB-ALL
Sto Concrete Block - Complete Detail Set (2.65mb)
PDF
STCB-ALL
Sto Therm Concrete Block - Complete Detail Set (2.20mb)
PDF

 

For a complete list of individual details, including CAD formats, please click here

 

CB-001
Sto Concrete Block - Introduction
DWGDXFPDF
CB-002
Sto Concrete Block - Index Sheet
DWGDXFPDF
CB-100
Sto Concrete Block Construction
DWGDXFPDF
CB-101
Sto Concrete Block Plaster System
DWGDXFPDF
CB-102
StoArmat Miral Plaster System - Cross Section
DWGDXFPDF
CB-103
Sto Concrete Block Mesh Layout
DWGDXFPDF
CB-200
Sto Concrete Block Foundation
DWGDXFPDF
CB-201
Sto Concrete Block Foundation - Insulating Plaster
DWGDXFPDF
CB-202
Sto Tanking to Concrete Block Retaining Walls
DWGDXFPDF
CB-300
Sto Concrete Block Horizontal/Sloping Soffit
DWGDXFPDF
CB-301
Sto Concrete Block Inclining Soffit
DWGDXFPDF
CB-302
Sto Concrete Block Parapet Top
DWGDXFPDF
CB-400
Sto Concrete Block Control Joints
DWGDXFPDF
CB-401
Sto Concrete Block Expansion Joint (Dissimilar Materials)
DWGDXFPDF
CB-402
Sto Concrete Block Expansion Joint (Dissimilar Materials)
DWGDXFPDF
CB-403
Sto Concrete Block Floor Transition Detail
DWGDXFPDF
CB-404
Sto Concrete Block Roof Membrane Flashing Detail.
DWGDXFPDF
CB-405
Sto Concrete Block Weatherboard Joint.
DWGDXFPDF
CB-550
Sto Concrete Block Aluminium Head/Sill Detail.
DWGDXFPDF
CB-551
Sto Concrete Block Aluminium Head/Sill
DWGDXFPDF
CB-552
Sto Concrete Block Timber Head/Jamb/Sill Detail.
DWGDXFPDF

 

STCB-001
StoTherm Concrete Block - Introduction
DWGDXFPDF
STCB-002
StoTherm Concrete Block - Index Sheet
DWGDXFPDF
STCB-100
StoTherm Insulation System - Cross Section
DWGDXFPDF
STCB-101
StoTherm Concrete Block EPS Overlay Plaster System
DWGDXFPDF
STCB-102
StoATherm Panel Layout
DWGDXFPDF
STCB-103
StoTherm Panel & Fixing Layout
DWGDXFPDF
STCB-104
StoTherm concrete Block Fixing Detail
DWGDXFPDF
STCB-200
StoTherm Concrete Block Foundation Detail
DWGDXFPDF
STCB-201
StoTherm Concrete Block Foundation in Ground
DWGDXFPDF
STCB-300
StoTherm Concrete Block Inclining Soffit
DWGDXFPDF
STCB-301
StoTherm Concrete Block Horizontal/Sloping Soffit
DWGDXFPDF
STCB-400
StoTherm Concrete Block Control Joints
DWGDXFPDF
STCB-401
StoTherm Concrete Block Weatherboard Transition
DWGDXFPDF
STCB-500
StoTherm Concrete Block Downpipe & Handrail Fixing Detail
DWGDXFPDF
STCB-550
StoTherm Concrete Block Aluminium Head/Jamb/Sill
DWGDXFPDF
STCB-551
StoTherm Concrete Block Face Fixed Aluminium Joinery
DWGDXFPDF

 

Click here to hide details.

 

Disclaimer: These drawings have been issued as a guideline. The sequence work covers various building components, each trade is responsible to ensure their elements are fully installed, including all waterproofing / sealant / flashings as is applicable.

 

Last updated August 2011