StoTherm Masonry
StoTherm Masonry Insulation System - BRANZ Appraisal Certificate 604 (2008)
New requirements for better energy efficiency
In August 2007 the Department of Building and Housing announced major changes to Clause H1 of the Building Code, which deals with energy efficiency, thermal storage and insulation. The changes include, amongst other things, increased insulation requirements and the increased recognition of the appropriate use of thermal mass. The changes affect all houses, and other buildings that have a floor area less than 300m2.
|
|
Internal Insulation (must meet timber R-V) StoTherm-Masonry Insulation R-V R-V R-V Masonry 60mm (meets all R-V 80mm (meets all R-V 100mm (meets all R-V (standard 100x50 framing) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Different insulation options have different effects on the physical properties of a building.
Sto's External insulation offers significant advantages; it offers a favourable temperature curve and shields the substrate from thermal shocks. There are no cold bridges and the existing heat retention capabilities of solid masonry walls are fully utilised, interstitial condensation can be eliminated irrespective of climate conditions. The internal wall temperature increases which reduces the risk of condensation, damp and mould.While internal insulation allows a room to be heated quickly, that's about its only plus point. Its temperature curve is poor, and the external wall remains vulnerable to the elements. The heat retention capability of the existing wall is not utilised in winter, and it is susceptible to an internal dew point resulting in condensation, damp and mould. In summer the process is reversed with the masonry wall heating the interior environment. Note: When insulating internally only, masonry walls need to meet the timber insulation requirements.
Download brochures for your electronic reference or product library.
Download brochures for your electronic reference or product library.
StoTherm Masonry System
StoTherm Classic Masonry has now been the international benchmark in the field of facade insulation for over 40 years.
Its shock proof and impact resistance is up to 6 times higher
than that of mineral cement based systems offering the utmost in fracture prevention. It consists of a co-ordinated systematic approach providing the optimum insulation requirements for concrete block construction. For a component break-down of the StoTherm Insulation System, please refer to the StoArmat Miral StoTherm Insulation System brochure.
Click on each of the layers below to see the components of the StoTherm Masonry System.

01
Adhesive: Gluecoat Mortar
02
Insulation: Expanded Polystyrene Sheet
60/100mm "H" grade self-extinguishing sheet, manufactured to AS 1366 Part 3 by an approved manufacturer.

03
Sto Therm Anchor
The Anchors are installed countersunk and capped with ST Insulation Cap to avoid thermal bridging.
Click here to view the procedure.
04
Basecoat: LevelLite 6/8 mm
Lightweight EPS bead mineral plaster with good build properties, water retention agents and machine application properties.

05
Reinforcement: StoArmat RFP
European manufactured and certified, strong, malleable, impact resistant, white reinforcing plaster in a pail. Contains a calibration grain ensuring correct mesh coat thickness. (No cement)

06
Plus: Sto European mesh
Easy to install, meets the highest requirements for crack, stress and alkalinity resistance.

07
Finishing Render: Stolit range
European manufactured and certified, organically
bound, strong, hard wearing, impact resistant, pre
coloured finishing renders. (No cement)

Stolit K - (1mm/1.5mm/2mm/3mm)coloured finishing render. A range of coloured float finished self gauging granulated finishes.
Stolit MP & MP Natural - coloured finishing render. A range of coloured fine sponge finishes.
08
Coating:
StoColor Maxicryl - matt facade paint.
StoLastic Color - satin matt facade paint European manufactured and certified durable facade paints available in a full range of colours.
Click here to download the TDS.
StoLotusan Color G - mineral silicone resin European manufactured and certified self cleaning mineral paint with a breathable structure, in a full range of colours. Not recommended in dark or strong tints.
.
Stolit: Coloured Finishing Renders
Stolit organic finishing renders are manufactured in Europe and certified around the world. They have been in successful use for over 50 years on a variety of different substrates. During this time they have undergone a continual process of optimisation.
The perfect combination of properties:Durable, strong, hardwearing, impact resistant, malleable, weather resistant, colour stable and highly resistant to micro-organism. They are designed with good vapour permeability to allow the building to breathe while still repelling liquid water. All renders are easy to apply and can be tinted from the StoColor System or matched to the colour of your choice, using the Sto spectrometer.
Coloured Self-Gauging Float Finish Renders: |
|||
![]() |
![]() |
![]() |
![]() |
StolitK 1.0mm |
StolitK 1.5mm |
StolitK 2.0mm |
StolitK 3.0mm |
StoTherm Classic System: |
|||
![]() |
![]() |
||
Stolit MP |
Stolit MP Natural |
The Perfect Finish: Competence in Colour

Download a technical specification for StoTherm Masonry from the list below. This specification is also integrated into the MasterSpec - 4282 SR - Masonry. (StoTherm Masonry) and 4285 S - Insulation (StoTherm). If you have any questions, please do not hesitate to contact us for technical support.
StoArmat Miral and StoTherm is appraised by BRANZ. Click below to download the BRANZ Appraisal Certificate.
Download CAD or PDF details for your project. Use the interactive detail selector below - roll over the hot spots to find and download the appropiate detail:
CB-200
Sto Concrete Block Foundation
CB-201
Sto Concrete Block Foundation - Insulating Plaster
CB-400
Sto Concrete Block Control Joints
CB-401
Sto Concrete Block Expansion Joint Between Dissimilar Materials
CB-550
Sto Concrete Block Aluminium Head / Sill Detail
CB-552
Sto Concrete Block Timber Head / Jamb / Sill Detail
Alternatively, select the link below to download a complete set of details below:
For a complete list of individual details, including CAD formats, please click here
Disclaimer: These drawings have been issued as a guideline. The sequence work covers various building components, each trade is responsible to ensure their elements are fully installed, including all waterproofing / sealant / flashings as is applicable.
Last updated August 2011